CONSTRUCTION MATERIALS · FIBRE CEMENT BOARD
Cemboard.
Choose the right system for floors, walls and ceilings.
Start with the installation location, service loads and water exposure. Check the board code, support framing, fasteners and joints against the same assembly detail. This helps buyers order the right materials and installers know what to inspect before covering the work.
What is Cemboard?
Here, Cemboard refers to fibre-reinforced cement boards. Identify the manufacturer, product range and exact board code when reviewing a quote. The same trade description may cover different specifications and applications.
- Portland cement forms the inorganic binder matrix.
- Cellulose fibres reinforce the cement matrix in products that use them.
- Silica or fine sand, water and mineral additives are blended to the manufacturer's formulation for each product. Check the declared composition and safety data sheet (SDS) for the exact board code.
Which documents address health and environmental concerns?
In use: choose a board documented as asbestos-free and suitable for the installation location. Where indoor emissions are specified, check the relevant test report for the exact product.
During fabrication: cutting, drilling or grinding may release dust containing respirable crystalline silica. Follow the SDS and manufacturer instructions, capture dust at source, wear suitable protection and clean up using methods that limit dust dispersal.
Environmental assessment: if the project requires life-cycle assessment, check the environmental product declaration (EPD) for the exact board where available. Include framing, cutting waste, transport and replacements when comparing options.
Read the board data
Check declared applications, dimensions, thickness, edge profile and exposure conditions.
Review the assembly details
Check drawings and installation instructions for supports, fastening, edges, joints and finishes.
Board selection by application
A common large format is 1,220 × 2,440 mm. Some ranges include 603 × 1,210 mm boards. Catalogue examples include 4 mm ceiling boards, 6 mm wall boards and 18–20 mm floor lining boards in selected ranges. Confirm the thickness and format against the drawings, service loads and approved assembly before ordering.
| Location | Information needed | What to confirm |
|---|---|---|
| Framed floor | Intended use, span, service loads and expected concentrated loads. | Floor-rated board code, support framing, edge supports, fastening layout and finish. |
| Interior partition | Wall height, door locations, services and suspended items. | Framing, number of board layers, reinforcement around openings and fixing points for suspended items. Where fire or acoustic ratings are specified, check the documentation for the whole assembly. |
| Ceiling | Interior or exterior location, openings and fixtures. | Board code, suspension, fixings and fixture supports as detailed in the approved assembly. |
| Wet or exterior area | Water contact, wind-driven rain, drainage direction and exposure conditions. | Board suitability, compatible fasteners and waterproofing details at corners, joints, pipe penetrations and exterior edges. |
Before ordering: take the board thickness, frame spacing and screw specification from the approved assembly. If the board code or framing changes, recheck the whole assembly before purchase.
What to confirm before requesting a quote
| Order information | What to send |
|---|---|
| Project and application | Floor, wall or ceiling. Include the installation location and water exposure. |
| Material specification | Board code, format, thickness and edge profile if available. Include drawings or framing details when they need review. |
| Documentation and accessories | List the required technical data, composition, test reports, screws and joint treatment materials. |
| Quantity and delivery | Area or board count, delivery address and quantity needed in each shipment. |
Short request template
Application …
Board code or known specification …
Quantity … · Delivery location … · Required date for each shipment …
Required documents or accessories …
Example: a framed floor in a washroom
Provide the layout, framing spans, fixture locations and floor drains to the design team. Confirm the floor assembly and reinforcement points, then detail the waterproofing, floor-to-wall junctions, pipe penetrations and tile finish. Include these in the pre-cover inspection. If a watertightness test is specified, record when it is required and who signs off.
Receiving and pre-cover checklist
On delivery
- Match the board code, thickness, edge profile and quantity to the order.
- Record the batch or identifier if available. Check for broken edges, cracks, warping or signs of water ingress.
- Set aside nonconforming or damaged boards for assessment before issuing them. Store boards as directed by the manufacturer.
Before covering
- Check the framing, edge supports and reinforcement against the drawings.
- Check fastening layouts, joints, perimeter edges, openings and penetrations.
- Record waterproofing inspection results where applicable. Photograph and mark the locations, then confirm deviations are resolved before proceeding.
Quick record: Area · Board code/batch · Applicable drawing · Checks completed · Deviations and corrective action · Photos · Sign-off · Date.
How does INDUSVINA help?
Source and documentation checks before delivery
INDUSVINA imports directly or buys from domestic manufacturers. We check the board code, origin and batch against technical data, composition declarations, physical and chemical properties and the test reports required by the project. If documentation is missing or specifications differ, we hold the batch for review before delivery.
Free delivery on the agreed schedule
INDUSVINA delivers free of charge to the agreed location, in batches matching the quantities and dates in the quote or order. The site can receive what it needs for each installation stage, reducing stock and storage costs.
When comparing factory-direct purchases or other channels, compare quotes with the same scope of documentation, transport charges, delivery batches and site stock requirements.
Send specifications for a quoteUnsure of the specification? Send the application, estimated quantity and delivery location if known.
Explore INDUSVINA
FROM SPECIFICATION TO SUPPLY
Which project needs
Cemboard?
Send the application, known specifications, quantity, delivery location and required dates. You can submit a request with the information you have.
INDUSVINA — SAFETY · SPEED · EFFICIENCY · WELL-BEING · TRUST.
ACCURATE · COMPLETE · CLEAN · PRACTICAL.








